Basic Info.
Products Name
IMC Conduit
Wall Thickness
1.75-3.88mm
Length
3050mm
Outside Diameter
20.7-113.4mm
Transport Package
Woven Plastic Bag
Specification
1/2"-4"
Trademark
RIFI
Origin
China
Production Capacity
250 Ton/ Month
Product Description
UL 6 hot dip galvansing Rigid Electrical Pipe 2"rigid conduit electrical metal conduit
Description:
UL 6 hot dip galvansing Rigid Electrical Pipe 2"rigid conduit electrical metal conduit
Type Name : Electrical conduit , hot dip galvanized electrical conduit , Galvanized Rigid Conduit,rgs conduit.
Brand Name: RIFI
Material:carbon steel
Surface treatment:hot dipped galvanized
Place of origin:China
Size:1/2"-4"
Length : 3050mm or as customer request length
Thickness : standard or thinnner or as customer request thickness are avvailable
Specification :
UL 6 hot dip galvansing Rigid Electrical Pipe 2"rigid conduit electrical metal conduit
Application:
Rigid conduit, often referred to as Rigid Metal Conduit (RMC) or Rigid Steel Conduit (RSC), is a thick-walled, heavy-duty electrical conduit used primarily for the protection and routing of electrical wiring in demanding and hazardous environments
Industrial Facilities: Rigid conduit is commonly used in industrial settings, including manufacturing plants, chemical facilities, and refineries. Its robust construction provides excellent protection for electrical wiring in areas with heavy machinery and potential physical hazards.
Commercial Buildings: In commercial buildings such as office complexes and retail spaces, rigid conduit is used for wiring protection, especially in areas prone to mechanical damage, like storage rooms, maintenance areas, and parking garages.
Outdoor and Underground Installations: Rigid conduit is suitable for outdoor applications where wiring needs protection from weather conditions, moisture, and UV radiation. It's also used in underground installations, providing a strong shield against soil and environmental factors.
Mechanical Rooms: In buildings with extensive mechanical equipment, like HVAC systems and large-scale machinery, rigid conduit is used to protect wiring in mechanical rooms.
Bridge and Tunnel Wiring: Rigid conduit is commonly used in the construction of bridges and tunnels to protect electrical wiring against the harsh environmental conditions, including exposure to water and extreme temperatures.
Data Centers: For critical power distribution systems in data centers and server rooms, rigid conduit is employed to safeguard electrical wiring and maintain reliable operations.
Transportation Infrastructure: Rigid conduit is used in transportation applications such as airports, subway systems, and train stations to protect electrical wiring for lighting, communication, and signaling systems.
Renovations and Upgrades: During building renovations or system upgrades, rigid conduit may be installed to replace or supplement existing conduit systems, ensuring compliance with safety regulations and protection standards.
Packing & shipping
UL 6 hot dip galvansing Rigid Electrical Pipe 2"rigid conduit electrical metal conduit
FAQ
Q1: Are you a trading company or manufacturing company?
A: Both we are, we have 2 production bases and about 10 sourcing factory to meet customer whole line items demand .
Q2:When can I get the quotation?
A1:For regular items within 24 hours; For sprcial items or customize items need a little more time .
Q3: How can I request product samples?
A: The samples are free but courier charge will be collected. Please send us samples list and courier account number.
Q4: How can I request a product catalog?
A: Pls send us your email and we will send you our e catalog ( pdf file ).
The PDF catalog we can send to you by email or WeTransfer.
Q5: What is your payment terms?
A:Normally 30% T/T deposit,balance against B/L copy;
the other is irrevocable L/C 100% at sight.
Q6: How about the delivery time?
A: Accord to your order list and quantity,mostly delivery in 30days.
Q7: How do we control the products' quality?
A: 1. high quality mold
2. raw materials control
3. production process quality control
4. final inspection
5. water testing (no leaking)
Description:
UL 6 hot dip galvansing Rigid Electrical Pipe 2"rigid conduit electrical metal conduit
Type Name : Electrical conduit , hot dip galvanized electrical conduit , Galvanized Rigid Conduit,rgs conduit.
Brand Name: RIFI
Material:carbon steel
Surface treatment:hot dipped galvanized
Place of origin:China
Size:1/2"-4"
Length : 3050mm or as customer request length
Thickness : standard or thinnner or as customer request thickness are avvailable
Specification :
UL 6 hot dip galvansing Rigid Electrical Pipe 2"rigid conduit electrical metal conduit
Trade size | Outside Diameter | Wall Thickness | Length | |||
inch | mm | inch | mm | feet | mm | |
1/2" | 0.840 | 21.34 | 0.104 | 2.64 | 10 | 3050 |
3/4" | 1.050 | 26.67 | 0.107 | 2.72 | 10 | 3050 |
1" | 1.315 | 33.40 | 0.126 | 3.20 | 10 | 3050 |
1-1/4" | 1.660 | 42.16 | 0.133 | 3.38 | 10 | 3050 |
1-1/2" | 1.900 | 48.26 | 0.138 | 3.51 | 10 | 3050 |
2" | 2.375 | 60.33 | 0.146 | 3.71 | 10 | 3050 |
2-1/2" | 2.875 | 73.03 | 0.193 | 4.90 | 10 | 3050 |
3" | 3.500 | 88.90 | 0.205 | 5.21 | 10 | 3050 |
3-1/2" | 4.000 | 101.60 | 0.215 | 5.46 | 10 | 3050 |
4" | 4.500 | 114.30 | 0.225 | 5.72 | 10 | 3050 |
5" | 5.563 | 141.30 | 0.245 | 6.22 | 10 | 3050 |
6" | 6.625 | 168.30 | 0.268 | 6.80 | 10 | 3050 |
Application:
Rigid conduit, often referred to as Rigid Metal Conduit (RMC) or Rigid Steel Conduit (RSC), is a thick-walled, heavy-duty electrical conduit used primarily for the protection and routing of electrical wiring in demanding and hazardous environments
Industrial Facilities: Rigid conduit is commonly used in industrial settings, including manufacturing plants, chemical facilities, and refineries. Its robust construction provides excellent protection for electrical wiring in areas with heavy machinery and potential physical hazards.
Commercial Buildings: In commercial buildings such as office complexes and retail spaces, rigid conduit is used for wiring protection, especially in areas prone to mechanical damage, like storage rooms, maintenance areas, and parking garages.
Outdoor and Underground Installations: Rigid conduit is suitable for outdoor applications where wiring needs protection from weather conditions, moisture, and UV radiation. It's also used in underground installations, providing a strong shield against soil and environmental factors.
Mechanical Rooms: In buildings with extensive mechanical equipment, like HVAC systems and large-scale machinery, rigid conduit is used to protect wiring in mechanical rooms.
Bridge and Tunnel Wiring: Rigid conduit is commonly used in the construction of bridges and tunnels to protect electrical wiring against the harsh environmental conditions, including exposure to water and extreme temperatures.
Data Centers: For critical power distribution systems in data centers and server rooms, rigid conduit is employed to safeguard electrical wiring and maintain reliable operations.
Transportation Infrastructure: Rigid conduit is used in transportation applications such as airports, subway systems, and train stations to protect electrical wiring for lighting, communication, and signaling systems.
Renovations and Upgrades: During building renovations or system upgrades, rigid conduit may be installed to replace or supplement existing conduit systems, ensuring compliance with safety regulations and protection standards.
Packing & shipping
UL 6 hot dip galvansing Rigid Electrical Pipe 2"rigid conduit electrical metal conduit
FAQ
Q1: Are you a trading company or manufacturing company?
A: Both we are, we have 2 production bases and about 10 sourcing factory to meet customer whole line items demand .
Q2:When can I get the quotation?
A1:For regular items within 24 hours; For sprcial items or customize items need a little more time .
Q3: How can I request product samples?
A: The samples are free but courier charge will be collected. Please send us samples list and courier account number.
Q4: How can I request a product catalog?
A: Pls send us your email and we will send you our e catalog ( pdf file ).
The PDF catalog we can send to you by email or WeTransfer.
Q5: What is your payment terms?
A:Normally 30% T/T deposit,balance against B/L copy;
the other is irrevocable L/C 100% at sight.
Q6: How about the delivery time?
A: Accord to your order list and quantity,mostly delivery in 30days.
Q7: How do we control the products' quality?
A: 1. high quality mold
2. raw materials control
3. production process quality control
4. final inspection
5. water testing (no leaking)